IAL Resources
The resources of the Integrated
Acoustics Laboratory principally are structured about three test
rooms: a full anechoic room, a semi-anechoic room, and a reverberation
room. The reverberation room and semi-anechoic room are joined
by a transmission loss opening. In addition to the test rooms,
the Active Control laboratory is an element of the IAL, with resources
focused on vibration control research.
Anechoic Room
The interior clear dimensions are 18' x
18' x 14'. The low frequency cutoff of the room is 80 Hz. Provisions
exist for installation of an expanded metal floor for heavier
test articles.
Semi-anechoic Room
The interior clear dimensions are 19.5'
x 25.7' x 14'. The low frequency cutoff is 80 Hz. The semi-anechoic
room and the reverb room are
joined by an 8' x 8' transmission loss opening.
Reverberation Room
The interior clear dimensions are 27' x
21' x 16.5'. The room is equipped with a rotating boom. Fixed
diffusors are currently being qualified per C423 performance.
The semi-anechoic room and the reverb room are joined by an 8'
x 8' transmission loss opening.
Instrumentation Supporting
the Test Rooms
- Anechoic room
- HP VXI data acquisition system with 32
channel 52 kHz A/D, 4-channel arbitrary source, 20 MHz A/D, 16
channel D/A, 4 GB local disk.
- HP C110 workstation as VXI front end,
LMS CADA-X system, Matlab acquisition
- Semi-Anechoic Room
- VXI Technology 16 channel data acquisition
system, 4-channel arbitrary source
- PC front end with Firewire interface to
VXI chassis
- Reverberation Room
- VXI Technology 16 channel data acquisition
system, 4-channel arbitrary source
- PC front end with Firewire interface to
VXI chassis
- DEC ALPHA analysis workstations (2)
- Software resources include LMS CADA-X,
MSC NASTRAN, COMET/Acoustics, LMS SYSNOISE
Related Instrumentation Resources
- Polytec PSV 2000 scanning laser vibrometer
- Large selection of Larson-Davis microphones,
preamplifiers, power supplies, calibrators
- Larson-Davis intensity probe, probe calibrators
- Larson-Davis model 824 , 820 and 800B
sound level meters
- Large selection of Kistler impact hammers
and accelerometers, including tri-axial accelerometers
- LDS exciter systems in 2, 5, 10 and 50
lbf range, and associated power supplies
- Aerodynamic sound power reference source
- Accelerometer and microphone calibrators
- 16 channel TEAC DAT recorder, 8 channel
Sony DAT recorder, variety of other recorders.
- Siglab DSP-50 two-channel anlyzer system
- Computer controlled rotational positioner
system
- Computer controlled X-Y positioner system